Psychiatric Services
Journal Home Search Current Issue Past Issues Subscribe All APPI Journals Help Contact Us
 
Psychiatr Serv 57:34-36, January 2006
doi: 10.1176/appi.ps.57.1.34
© 2006 American Psychiatric Association
Quicksearch
Advanced Search
Or Search All APPI Journals
This Article
* Full Text
* Full Text (PDF)
* Alert me when this article is cited
* Alert me if a correction is posted
Services
* Email this article to a Colleague
* Similar articles in this journal
* Similar articles in PubMed
* Alert me to new issues of the journal
* Add to My Articles & Searches
* Download to citation manager
* reprints & permissions
Citing Articles
* Citing Articles via Google Scholar
Google Scholar
* Articles by Currier, G. W.
* Articles by Walsh, P. G.
* Search for Related Content
PubMed
* PubMed Citation
* Articles by Currier, G. W.
* Articles by Walsh, P. G.
Related Collections
* Alcohol

Columns

Innovations: Emergency Psychiatry: Relative Accuracy of Breath and Serum Alcohol Readings in the Psychiatric Emergency Service

Glenn W. Currier, M.D., M.P.H., Adam J. Trenton, B.A. and Patrick G. Walsh, B.S.

Management of changes in physiologic and mental status due to alcohol is a core skill utilized in the psychiatric emergency service. Blood alcohol concentrations are commonly approximated by measuring breath alcohol at triage. However, the blood-breath ratio is highly variable, and breath tests have produced lower readings than blood tests. The authors assessed the accuracy of breath alcohol readings at triage in a medical emergency department compared with subsequent serum alcohol levels taken in the psychiatric emergency service. The mean breath ethanol concentration was significantly lower than the mean corrected serum ethanol concentration (.15±.05 grams per 210 liters and .23±.05 grams per 100 milliliters, respectively). The relative accuracy of breath alcohol tests decreased with increasing serum alcohol. Although its low false-positive rate makes the breath test acceptable for legal purposes, the blood alcohol level is more appropriate for clinical use in emergency settings, because breath tests can underestimate the degree of toxicity.







Get information about faster international access.

Privacy Policy

Copyright © 2006 American Psychiatric Association. All rights reserved.

Home | Search | Current Issue | Past Issues | Subscribe | All APPI Journals | Help | Contact Us

American Psychiatric Publishing, Inc. American Psychiatric Association
1000 Wilson Boulevard, Suite 1825, Arlington, VA 22209-3901 * 800-368-5777 * appi at psych.org